意大利pk10技巧

Welcome to visit Shenzhen Xinxin Technology official website cimnt.com

Consulting Hotline: 180-2532-0395

industrial control

X-ray diffractometer core circuit board clone case

Date: 2017-06-02

As a professional reverse research company, Xinxin Technology provides customers with reverse analysis and cloning of electronic products, including chip decryption, PCB copy board, foundry production and other technical services, and supports innovation and development based on reverse cloning. X-ray diffractometer is one of the successful cases of Xinxin Technology's industrial circuit board cloning. It has obtained the core technical information of this product, and can provide customers with secondary equipment modification and prototype cloning technology services for this equipment. Lower cost secondary development complete solution.

The following are the detailed technical parameters:

★ Tube voltage: 10 ~ 60kV is automatically controlled by computer terminal (1kV / step);
★ Tube current: 5 ~ 80mA is automatically controlled by the computer terminal (1mA / step);
★ Stability of tube voltage and tube current≤0.01%;
★ Rated output power: 3KW;
★ Over-voltage, over-current, over-power, no voltage, no water, X-ray tube over temperature protection;
★ The shutter switch is controlled automatically by the computer terminal;
★ System comprehensive stability ≤0.3%;
★ The protection system is double protection, and the shutter window is linked with the protective cover, and the lead door opens and closes the shutter automatically. The radiation protection meets the national standard requirements, not more than 0.3μSv / h;
main feature:
Adopting imported programmable logic controller (PLC) technology, which is controlled by the technology, has good anti-interference performance, and can achieve the failure-free rate of the high-voltage control part. The interface between PLC and microcomputer can realize that the microcomputer terminal can directly control the high-voltage switch of the instrument, the lift and the switch of the optical shutter. Make the instrument more automated. More stable performance.
The high-precision goniometer adopts an advanced shaft encoder structure with a minimum step angle of 0.001 °. It has a super low-angle scanning function, which can be started from the lowest 0.2 °, which is suitable for the study of small-angle diffraction.
1. X-ray generator (imported PLC control technology)
Imported PLC (programmable controller) control technology, high degree of automation, extremely low failure rate, anti-drying
Strong interference ability, good system stability, can extend the service life of the whole machine. PLC and computer interface automatically control the shutter
Switch, automatic control of pipe pressure, pipe flow rise and fall, with the function of automatic training X-ray tube.
★ Power supply voltage (single phase) AC 220V ± 10%
★ Rated power: 3kW
★ Tube voltage: 10 ~ 60kV, 1kV / Step
★ Tube current: 5 ~ 80mA, 1mA / Step
★ Stability: ≤0.01%
★ Protection function: It has no pressure, no current, over pressure, over current, no water, X-ray tube over temperature protection and other functions.
Goniometer
Use computer to control the rotation of the goniometer (step, retreat), and automatically perform angle correction to eliminate idle and
Lost step detection. With worm gear and worm structure, the goniometer has higher accuracy and longer service life.
★ Diffraction circle radius 185mm
★ 2θ scan range from 0 to 164 ° or -30 to 165 °
★ Scanning speed 0.005 ~ 1.27 ° / s or 0.3 ~ 76.2 ° / min
★ 2θ angle repeat accuracy≤0.001 °
★ Minimum measurement accuracy≤0.005 °
★ Minimum step angle≤0.001 °
3. Record control unit
Adopt advanced technology (PLC control technology) and advanced device based on imported Panaco diffractometer recording control technology
Software has made greater improvements to hardware and software systems.
★ Counter: Flicker counter
★ Counter high voltage: 0 ~ 2000V continuously adjustable
★ Counting method: Differential or integral method
★ High voltage stability of detector: better than ± 0.01%
★ Spectrum resolution: Flicker counter: ≤50%
4. Circulating refrigeration system:
Circulating water device with cooling function. The device automatically controls the water temperature and displays the X-ray tube temperature, and the temperature range can be automatically selected. The built-in refrigeration system eliminates the need for an external circulating water cooling device, and uses a stainless steel water pump to reduce noise and eliminate the occurrence of water rust, avoiding the blockage of the X-ray tube.
★ Structure: integrated or split
★ Working temperature: 0-50 ° C
★ Working voltage: 220V
★ Protection function: with cooling function, and automatically control temperature, display X-ray tube water temperature
5.High voltage transformer
★ Dielectric voltage: 100kV
6.X-ray tube
★ Power: 2kW
★ Focus: 1 × 10mm
★ Target: Cu, Mo, Co, Fe, Cr
7, X-ray protective cover
★ Scatter measurement: The radiation measurement outside the protective cover is not more than 0.3μSv / h.
8.Control software and application software
★ Control function: can automatically control the diffractometer system for continuous scanning or step scanning,
Data were collected at the same time. Diffraction peak measurement, net intensity measurement, goniometer rotation, angle measurement
The instrument steps and retreats, the goniometer adjusts 2θ calibration, tube current, tube voltage, and shutter control.

QQ Online Customer Service
Customer service Miss Xu Customer service Long Technical consultation
Scan QR code

Telephone consultation

0755-25885060 180-2532-0395